X8, X9, X10, X11 LED output channels

Prev Next

The following connector is required:

  • Würth Elektronik 691 325 110 006

The following counterpart is required:

  • Würth Elektronik 691 364 100 006

pin

name

description

1

V_ANODE

anode output LED line

2

V_CATHODE

cathode output LED line

3

COR_SCL

clock for external I2C bus (only valid with Corona II)

4

COR_SDA

data for external I2C bus (only valid with Corona II)

5

COR_GND

ground for external I2C bus (only valid with Corona II)

6

COR_VCC

supply for external I2C bus (only valid with Corona II)

When using Corona II LED modules the XLC4 control unit communicates via the I2C interface.

Limitation output voltage and output current

The 4 outputs are limited to the following parameters:

Parameter

Description

Min

Nominal

Max

IChannel

Operating current (per channel) [A]

0.2

1.8

V_ANODE

Output voltage [V]

17

46

Limitations output current of different LED colors

White and Infrared

Parameter

Description

Min

Norminal

Max

IChannel

Operating current (per channel) [A]

0.2

1.8

Red, green, blue

Parameter

Description

Min

Norminal

Max

IChannel

Operating current (per channel) [A]

0.2

1.5

UV

Parameter

Description

Min

Norminal

Max

IChannel

Operating current (per channel) [A]

0.2

1.0