Electrical installation
    • 07 Nov 2024
    • 2 Minutes to read
    • PDF

    Electrical installation

    • PDF

    Article summary

    DXGE interface

    The SFP+ 10 GigE connectors permit to use (direct attach) copper cables or optical fiber cables with lengths of up to 400 m (10GBASE-SR).

    • Use a single port for data rates up to 10 Gbit/s.
    • For higher data rates connect both ports using Link Aggregation.

    Network adapter

    To establish a DXGE connection a network adapter with one or two SFP+ 10 GigE inputs must be installed and configured on the PC. The installation of a network adapter is explained in the GCT documentation. For more information, see Installation GigE

    For more information about the tested network adapters and the transceivers, see Tested Network adapters and Transceivers.

    Cabling

    electricitygeneral warningWARNING
    Electric shock due to improper connection to a power supply.
    Use a 12 V – 24 V DC power supply.
    1. Connect one or both video output ports.
    2. Connect the digital I/O port.
    3. Connect the power supply.

    CXP interface

    The interface allows you to connect up to four CXP cables. Micro BNC (for CXP12) connectors for the camera and suitable connectors for the frame grabber are required. The maximum cable length is 35 m.

    Frame grabber

    To establish a CXP connection a frame grabber must be installed and configured on the PC. Refer to the manual of your frame grabber. 

    For more information about the tested frame grabbers, see Tested frame grabbers.

    Cabling

    electricitygeneral warningWARNING
    Electric shock due to improper connection to a power supply.
    Use a 12 V – 24 V DC power supply.
    1. Connect port 0 (master port) of the video output port.
      NOTE
      For the maximum line rate connect all four ports.
      Make sure that port 0 of the camera is connected to port 0 (or A) of the frame grabber. Otherwise, no connection to the camera can be established.
    2. Connect the digital I/O port.

    Option 1: Power over CoaXPress (PoC)

    To use the power-over-CXP function two connections are needed.

    Connect port 0 and port 1 of the video output port.

    Option 2: Power supply port

    Connect the power supply.

    Digital I/O port

    NOTE
    Ensure a proper GND connection of the digital camera I/O port and your trigger.  

    The following connector is required for the digital I/O port:

    • 15-pin HD D-Sub (male)

    evo-digital io_02Pin allocation D-Sub connector (female) of the camera

    PinGenICamSignalLevelIn/OutExample/Remark
    1Line 1
    Enc0_InP (+)
    RS 422
    Differential input
    Encoder0 or LineTrigger
    2Line 2
    Enc1_InP (+)
    RS 422
    Differential inputEncoder1 or Frametrigger
    3Line 3
    IO_0P
    LVCMOS
    Input
    single-ended
    4-RT
    RS 485
    --
    5Line 5
    IO_2P
    LVCMOS
    OutLED-Out1
    6Line 1
    Enc0_InN (-)
    RS 422
    Differential input
    Encoder0
    7Line 2
    Enc1_InN (-)
    RS 422
    Differential input
    Encoder1
    8Line 4
    IO_1N
    LVCMOS
    Input single-ended
    Trigger or Master-Slave Cascaded
    9-RTN
    RS 485
    Out
    To LightController XLC4
    10Line 6
    IO_3
    LVCMOS
    Out
    LED-Out2
    11-GND
    -GND-
    12Line 7
    IO_4_SDA
    LVCMOS
    Out
    LED-Out3
    13-GND
    GND
    --
    14Line 9Master/Slave
    LVCMOS
    Bi-directional
    Master/Slave
    15Line 8
    IO_5_SCL
    LVCMOS
    Out
    LED-Out4

    LVCMOS and RS422 levels

    I/O standardV_ILV_IHV_OLV_OH

    V_minV_maxV_minV_maxV_maxV_min
    LVCMOS–0.50.71.73.60.42.1
    RS422–60.826--
    noticeNOTICE
    Non compliance may cause irreparable damages to the device.
    The maximum input level of the LVCMOS is 3.6 V.
    Use a level converter if necessary (e.g. 74 LVC14).


    Circuit Diagrams

    RS422 configuration

    svg-neo-circuit_diagram_rs422External circuit:  RS422 device

    Single-Ended configuration

    svg-neo-circuit_diagram_1External circuit: Optocoupler

    svg-neo-circuit_diagram_2External circuit: TTL or CMOS logic gate  

    Power supply

    The following connector is required for the power supply cable:

    • Manufacturer: Hirose
    • Article no.: HR10A-7P-6S female

    PinDescription
    svg-evo-power supplyPin allocation of the power supply port

     

    1Power +24 V
    2Power +24 V
    3Not connected
    4Not connected
    5Ground
    6Ground