This instruction manual provides the necessary information for safe and efficient use of the product throughout its life cycle.
Representational tools
Font markup bold: clickable areas in the software GCT.
Font markup italic: windows and views to navigate to in the software GCT.
History of Documentation
Version 1.2.0
New features for GCT 2.7.0 release have been added, September 2024.
Offline Version
Download as PDF-File
Version 1.1.0
New features for GCT 2.5.0 release have been added, October 2023.
Version 1.0.0
The initial version of this Documentation is July 2023.
History of GCT
GCT 3.0.0 (April 2025)
Release Notes:
Changes and new features
Added multiple device support
Added color calibration wizzard
Added First / Each line info block analysis
Added popup for starting PRNU / DSNU
Added saving 10 and 12 bit images in MSB
Added default path file format on update/download
Added Windows redistributable 2017
Adjusted installer
Changed configuration widget for mono and RGBA cameras
Improved control experience on Windows 11
Improved formatting on high resolution screens
Improved plot ROI selection
Improved UI formatting on Windows 11
Modernized gct app look and feel
Made flash functionality visible for certain devices
Made network adapter configuration batch script run on Windows 11
Made Kithara Windows 11 compatible
Reduced amount of error messages in log window
Updated docs
Updated Kithara driver to 11.18
extend target value for infrared channel when generating prnu reference file
Bugfixes
Fixed trigger delay lines being overwritten
Fixed force IP when pressing set button
Fixed setting camera IP
Fixed enable trigger option when line is already in use
Fixed upload calibration file from camera to PC
Fixed load device description from disk
Fixed image display issue
Fixed set trigger delay lines on allPIXA neo
Fixed PRNU for mono camera
Fixed Flash Enable checkbox
Fixed opening 10 bit images that were too dark
Fixed crash when closing neo camera
Fixed ROI button for plot
Fixed brightness and contrast in PRNU Wizard
Fixed missing feature information
Fixed crash when using MONO8 pixel format images in PRNU
Fixed wrong pixel value in 10 and 12 bit reference image
GCT 2.8.0 (September 2024)
Release Notes:
Changes and new features
GCT checks the connectivity to the camera periodically adn informs the user if the camera connection is lost.
The design of FrameTrigger and LineTrigger plugins are modified and will be constructed based on the availability of "FrameBurst" feature.
Zoom functinality is added to the "Select ROI" window. Helps with increased correctness to select ROI.
DSNU and PRNU calibration data generation is extended for MONO8 type images.
Qt6 libraries are used to design the UI elements of GCT application.
In Performance-Tool application, Image-Info-block can be deactivated.
Modification in Kithara-TL for better error handling and suppressing error and warning messages.
Documentation of "Calibration_Generator" sample project is updated in the source file.
"TestPattern-Generator" and "User-Set-Control" plugin tabs are moved to "Acquisition-Control" tab.
Visual-Studio redistributable(14.40.33810.0) is added to the GCT-Installer application. The redistributable is installed by default.
Shading reference data(DSNU/PRNU) can be created from RGB10, RGB12, RGBA10 RGBA12, MONO10 and MONO12 images.
Bug fixes
Single channel view mode for offline mode images functioning is fixed.
In PRNU generation, correct calibration data will be generated with extrapolation and ROI setup.
User-set cannot be changed anymore during image acquisition.
GCT 2.7.1 (June 2024)
Release Notes:
Changes and new features
Outlier suppression will be done only for pixels in ROI area between the left and right extrapolation columns.
In DSNU/PRNU dialog, line plots and histograms will be updated and displayed for the the selected ROI region.
GCT recognizes that a camera has been powered off and disconnected and informs the user with a dialog.
User-set load button is disabled during streaming.
Bug fixes
Fixed problem in generating sample projects with cmake.
Histogram and line-plots are displayed for the image captured in Frame-trigger mode.
Fixed Select-ROI feature of line plots in DSNU/PRNU generator dialog.
Exposure time is updated properly when line-rate is changed.
Single-channel view functions properly in the offline mode.
Bugs in PRNU reference data creation with extrapolation are fixed.
GCT 2.7.0 (April 2024)
Release Notes:
Changes and new features
New Functions added to CSI SDK
SDK Functions to generate calibration data and upload it to camera and save the file in PC is added.
A new sample to demonstrate usage of DSNU/PRNU generator SDK functions.
Opening and displaying 10 bit and 12 bit images in GCT viewer.
Images can be saved in LZW compressed TIFF format.
In the Adjustment tool, the view type, single view channel is enabled.
Mono image's line-plot and histogram feature is enabled.
A message box for un-/successful load/save of user-set is displayed.
Bug fixes
Spin boxes in Flash-controller plugin are disabled during streaming.
Added "Image Count" section in the status bar of the central viewer.
Added the possibility to save histogram and plot views.
The image will be saved only if there is sufficient memory available in the PC.
Right histogram and line-plots are displayed for last captured image, in frame-trigger mode.
Fixed GCT-crash issue in master-slave mode device connection.
The right device error code and description are displayed in a message box.
The right range of axes values in lineplots and histograms can be set.
GCT 2.6.1 (January 2024)
Release Notes:
Bug Fixes
fixed bug of setting led flash pattern duration incorrectly in the configuration widget Flash controller.
fixed bug of setting color transformation value incorrectly in the configuration widget Color.
fixed bug of DSNU/PRNU not working for 16k image.
GCT 2.6.0 (December 2023)
Release Notes:
Changes and new features
a new view type "vertical line plot" has been added.
improved "horizontal line plot" ui.
added link to online documentation.
a function for saving 10- and 12-bit Tiff images in GCT has been added.
added support for saving compressed TIFF files.
refactored the line trigger plugin and frame trigger plugin.
updated Kithara driver to 11.13.
Changed obsolete names
Kithara driver from LakesightDrv to TKHVision.
Kithara GenTL from ls_tl_gev_kithara.cti to tkh_tl_gev_kithara.cti.
Bug Fixes
fixed streaming image issue with Kithara TL when stop acquisition.
fixed general problem of image acquisition.
fixed bug in configuration widget for sensor sensitivity of mono cameras.
GCT 2.5.0 (October 2023)
Download the Documentation for GCT Version 2.5.
Release Notes:
Added split view functionality
Improvements in DSNU/PRNU: Calculation improvement to suppress outliers like dust areas, Improvement to specify roi
Added image buffer for image
Updated Filter Driver to V2.7.2
Updated Kithara Driver to 11.12
Performance Tool using CSI API
The SDK function "csiGetNextImage" has been modified. The second function argument is changed from csiNewBufferEventData* to csiNewBufferEventData**. This output variable that contains the acquired image data must be modified accordingly
A new view-type "Single-channel" is added. This view type displays just the selected channel's image data onto the image view
Bugfixes
GCT 2.4.0 (May 2023)
Download the Documentation for GCT Version 2.4.
GCT 2.3.0
Download the Documentation for GCT Version 2.3.