User Set Control
    • 02 Jul 2024
    • 1 Minute to read
    • PDF

    User Set Control

    • PDF

    Article summary

    Loaded User Set

    Name

    LoadedUserSet

    Custom

    Description

    Specifies the last loaded user set.

    Interface

    String

    String length

    32

    Access mode

    Read Only

    Adjustable

    while grabbing

    Yes

    Value range

    -

    Default value

    Default

    Availability

    ALL

    Notes

    -

    Error behavior

    See the device error code documentation.

    User Set Selector

    Name

    UserSetSelector

    Standard

    Description

    Selects the feature User Set to load, save or configure.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    Yes

    Value range

    See enum entries table below.

    Default value

    UserSet1

    Availability

    ALL

    Notes

    -

    Error behavior

    See the device error code documentation.

    User Set Selector Enum Entries:

    Name

    Description

    UserSet1

    Selects the UserSet 1

    UserSet2

    Selects the UserSet 2

    UserSet3

    Selects the UserSet 3

    UserSet4

    Selects the UserSet 4

    UserSet5

    Selects the UserSet 5

    UserSet6

    Selects the UserSet 6

    UserSet7

    Selects the UserSet 7

    UserSet8

    Selects the UserSet 8

    Default

    Selects the Default

    User Set Load

    Name

    UserSetLoad[UserSetSelector]

    Standard

    Description

    Loads the User Set specified by UserSetSelector to the device and activates it.

    Interface

    Command

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    1

    Default value

    1

    Availability

    ALL

    Notes

    -

    Error behavior

    See the device error code documentation.

    User Set Save

    Name

    UserSetSave[UserSetSelector]

    Standard

    Description

    Save the current user settings to the selected user set in the non-volatile memory of the device.

    Interface

    Command

    Access mode

    Read/Write

    Adjustable

    while grabbing

    Yes

    Value range

    1

    Default value

    1

    Availability

    ALL

    Notes

    Default is Read only.

    Error behavior

    See the device error code documentation.

    User Set Comment

    Name

    UserSetComment[UserSetSelector]

    Custom

    Description

    Leave a comment here to describe the chosen setting.

    Interface

    String

    String length

    32

    Access mode

    Read/Write

    Adjustable

    while grabbing

    Yes

    Value range

    -

    Default value

    Default

    Availability

    ALL

    Notes

    Default user set is Read only.
    When executing User Set Save the comment of the active user set is stored to flash.

    Error behavior

    See the device error code documentation.


    Was this article helpful?