- 27 Feb 2024
- 1 Minute to read
- Print
- PDF
Set up communication to the XLC4 controller
- Updated on 27 Feb 2024
- 1 Minute to read
- Print
- PDF
Switching the illumination on and off via the camera
The following section describes how to connect the camera to the LED Control Unit XCL4 to switch the illumination ON and OFF via the frame active signal. The configuration is used to automatically turn ON the illumination as a frame acquisition is started and turn OFF the illumination after the acquisition.
Wiring
Note
You need a electrical grounding (protective earth) for your camera and LED Control Unit XLC4.
Therfore connect the housing of your camera and LED Control Unit XLC4 housing to your electrical ground.
Also connect the power supply input X4 Pin 3 and 4 of your LED Control Unit XLC4 to your electrical ground.
Connect the following pins of the LED Control Unit XCL4 (connector X6) to the digital I/O port (15 pin HD D-Sub) of the camera.
Step | LED Control Unit XLC4 (Connector X6) | Camera (15 pin HD D-Sub) |
---|---|---|
1 | PIN 1 (Signal) | PIN 11 or 12,13,14 |
2 | PIN 6 (GND) | PIN 5 (GND) |
Configure the LED Control Unit XLC4
Control Flad A
The configuration of the Control Flag A of the LED Control Unit XLC4 is done with the FA command. You need to add the 0×0020 to your current configuration and send it with the XLC4 commander software to your controller. Refer to the LED Control Unit XLC4 Manual Page 101.
Example: If you also using a fan you need the command 0×002C.
Note
After a FA command of the LED Control Unit XLC4 you need to power cycle the controler.
Command MO (set operation mode)
The configuration of the operation mode of the LED Control Unit XLC4 is done with the MO command. You need to set the Command Mode in your controller, therefore send the command MO 1 with the XLC4 commander software to your controller. Refer to the LED Control Unit XLC4 Manual Page 97.
Configure the camera
To configure the camera set the following parameter in the camera feature tree.
| |
| |
|