- 06 Sep 2024
- 2 Minutes to read
- Print
- PDF
Lighting Control – Not Available for AllPIXA-EVO
- Updated on 06 Sep 2024
- 2 Minutes to read
- Print
- PDF
Light Controller Set Load
Name | LightControllerSetLoad | Custom |
Description | Loads the Light Controller Set to the device and actives it. | |
Interface | Command | |
Access mode | Read/Write | |
Adjustable while grabbing | - | |
Value range | 1 | |
Default value | 1 | |
Notes | - | |
Error behavior | - |
Light Controller Set Save
Name | LightControllerSetSave | Custom |
Description | Save the Light Controller Set to the non-volatile memory of the device. | |
Interface | Command | |
Access mode | Read/Write | |
Adjustable while grabbing | - | |
Value range | 1 | |
Default value | 1 | |
Notes | - | |
Error behavior | - |
Light Controller Scan Devices
Name | LightControlScanDevices | Custom |
Description | Performs a scan for XLCs. | |
Interface | Command | |
Access mode | Write only | |
Adjustable while grabbing | - | |
Value range | 1 | |
Default value | 1 | |
Notes | - | |
Error behavior | - |
Light Controller Scan Status
Name | LightControllerScanStatus | Custom |
Description | Displays Light Controller scan status information. | |
Interface | Enumeration | |
Access mode | Read only | |
Adjustable while grabbing | - | |
Value range | See enum entries table below. | |
Default value | - | |
Notes | - | |
Error behavior | - |
Light Controller Scan Status Enum Entries:
Name | Description |
NoScanExecuted | No scan executed |
ScanInProgress | Scan in progress |
ScanFinished | Scan finished |
Light Controller Detected Devices
Name | LightControllerDetectedDevices | Custom |
Description | The bit position represents the on/off state of the light controller. | |
Interface | Integer | |
Access mode | Read only | |
Adjustable while grabbing | - | |
Value range | ≥0 | |
Default value | - | |
Notes | - | |
Error behavior | - |
Light Controller General Error
Name | LightControllerGeneralError | Custom |
Description | Displays Light Controller General Error Information. | |
Interface | Enumeration | |
Access mode | Read/Write | |
Adjustable while grabbing | - | |
Value range | See enum entries table below. | |
Default value | - | |
Notes | - | |
Error behavior | - |
Light Controller General Error Enum Entries:
Name | Description |
No Error | NoError |
Communication Not Enabled | CommunicationNotEnabled |
No Device Available | NoDeviceAvailable |
Device Not Available | DeviceNotAvailable |
Invalid Controller Selector | InvalidControllerSelector |
Invalid Channel Selector | InvalidChannelSelector |
Link May Be Broken | LinkMayBeBroken |
Invalid ID | InvalidID |
ID Already Assigned | IDAlreadyAssigned |
Light Controller Selector
Name | LightControllerSelector | Standard |
Description | Selects the Light Controller to configure. | |
Interface | Enumeration | |
Access mode | Read/Write | |
Adjustable while grabbing | - | |
Value range | See enum entries table below. | |
Default value | - | |
Notes | - | |
Error behavior | - |
Light Controller Selector Enum Entries:
Name | Description |
LightControllerBroadcast | Light Controller Broadcast |
LightController2 | Light Controller 2 |
LightController3 | Light Controller 3 |
LightController4 | Light Controller 4 |
LightController5 | Light Controller 5 |
LightController6 | Light Controller 6 |
LightController7 | Light Controller 7 |
LightController8 | Light Controller 8 |
LightController9 | Light Controller 9 |
LightController10 | Light Controller 10 |
LightController11 | Light Controller 11 |
LightController12 | Light Controller 12 |
LightController13 | Light Controller 13 |
LightController14 | Light Controller 14 |
LightController15 | Light Controller 15 |
Light Connection Status
Name | LightConnectionStatus | Standard |
Description | Status of a light connected to the controller’s output line. | |
Interface | Enumeration | |
Access mode | Read only | |
Adjustable while grabbing | - | |
Value range | See enum entries table below. | |
Default value | - | |
Notes | - | |
Error behavior | - |
Light Connection Status Enum Entries:
Name | Description |
Sensing | Sensing |
Ready | Ready |
NoConnect | No connect |
ResponseError | Response error |
Error | Error |
Light Controller Reset
Name | LightControllerReset | Custom |
Description | Resets the selected XLC. | |
Interface | Command | |
Access mode | Write only | |
Adjustable while grabbing | - | |
Value range | 1 | |
Default value | 1 | |
Notes | - | |
Error behavior | - |
Light Controller Assign ID
Name | LightControllerAssignID | Custom |
Description | Represents the current Light Controller ID and changes it if another one has been entered. | |
Interface | Integer | |
Access mode | Read/Write | |
Adjustable while grabbing | - | |
Value range | - | |
Default value | - | |
Notes | - | |
Error behavior | - |
Light Controller Input Voltage
Name | LightControllerInputVoltage | Custom |
Description | Displays the Light Controller input voltage. | |
Interface | Integer | |
Access mode | Read only | |
Adjustable while grabbing | - | |
Value range | - | |
Default value | - | |
Notes | The unit is mV. | |
Error behavior | - |
Light Controller Detailed Error Information
Name | LightControllerDetailedErrorInformation | Custom |
Description | Detailed error information about the selected light controller. | |
Interface | Enumeration | |
Access mode | Read only | |
Adjustable while grabbing | - | |
Value range | See enum entries table below. | |
Default value | - | |
Notes | - | |
Error behavior | - |
Light Controller Detailed Error Enum Entries:
Name | Description |
NoError | No Error |
InvalidCommando | Invalid Commando |
InvalidParameter | Invalid Parameter |
Parameter | Parameter |
CommandNotSupported | Command Not Supported |
InputVoltage | Input Voltage |
AnalogVoltage | Analog Voltage |
LedOutput | Led Output |
FailNoSignal | Fail No Signal |
TemperatureWarning | Temperature Warning |
TemperatureError | Temperature Error |
ShutdownSignal | Shutdown Signal |
EepromWriteDriverUnit | EEPROM Write Driver Unit |
EepromReadDriverUnit | EEPROM Read Driver Unit |
EepromWriteLed | EEPROM Write LED |
EepromReadLed | EEPROM Read LED |
Fan | Fan |
AnalogOutputVoltage | Analog Output Voltage |
SeeGeneralError | See General Error |
Light Controller Serial Number
Name | LightControllerSerialNumberReg | Custom |
Description | Serial Number of the Light Controller | |
Interface | String | |
String Length | 32 | |
Access mode | Read only | |
Adjustable while grabbing | - | |
Value range | - | |
Default value | - | |
Notes | - | |
Error behavior | - |
Light Controller Channel Selector
Name | LightControllerChannelSelector | Custom |
Description | Selects the Light Controller Channel to configure. | |
Interface | Enumeration | |
Access mode | Read/Write | |
Adjustable while grabbing | - | |
Value range | See enum entries table below. | |
Default value | - | |
Notes | - | |
Error behavior | - |
Light Controller Selector Enum Entries:
Name | Description |
LightControllerChannelA | Light Controller Channel A |
LightControllerChannelB | Light Controller Channel B |
LightControllerChannelC | Light Controller Channel C |
LightControllerChannelD | Light Controller Channel D |
LightControllerChannelBroadcast | Light Controller Channel Broadcast |
Light Current Rating
Name | LightCurrentRating | Standard |
Description | Set the current rating of the lighting output. | |
Interface | Float | |
Access mode | Read/Write | |
Adjustable while grabbing | - | |
Value range | ≥0 | |
Default value | - | |
Notes | The unit is Amp. | |
Error behavior | - |
Light Enable
Name | LightEnable | Custom |
Description | Controls the light for the selected Lighting Controller. | |
Interface | Boolean | |
Access mode | Read/Write | |
Adjustable while grabbing | - | |
Value range | True – Enables the selected lighting controller False – Disables the selected lighting controller | |
Default value | - | |
Notes | - | |
Error behavior | - |
Light Controller Driver Temperature
Name | LightControllerDriverTemperatureReg | Custom |
Description | Light Controller Driver Temperature | |
Interface | Integer | |
Access mode | Read only | |
Adjustable while grabbing | - | |
Value range | - | |
Default value | - | |
Notes | The unit is degrees Celsius. | |
Error behavior | - |
Light Controller Luminant Temperature
Name | LightControllerLuminantTemperatureReg | Custom |
Description | Light Controller Luminant Temperature | |
Interface | Integer | |
Access mode | Read only | |
Adjustable while grabbing | - | |
Value range | - | |
Default value | - | |
Notes | The unit is degrees Celsius. | |