Led Flash Control
    • 02 Jul 2024
    • 2 Minutes to read
    • PDF

    Led Flash Control

    • PDF

    Article summary

    Led Flash Enable

    Name

    LedFlashEnable

    Custom

    Description

    Enables Led flashing feature to support LED drivers with strobe signals for flashing

    Interface

    Boolean

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    True – Led flash is enabled

    False – Led flash is disabled

    Default value

    False

    Availability

    ALL

    Notes

    -

    Error behavior

    See the device error code documentation.

    Led Flash Number of Pattern

    Name

    LedFlashNumberOfPattern

    Custom

    Description

    Number of Led Flash pattern per flashing sequence

    Interface

    Integer

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    [1 , 4]

    Default value

    1

    Availability

    ALL

    Notes

    -

    Error behavior

    See the device error code documentation.

    Led Flash Pattern Selector

    Name

    LedFlashPatternSelector

    Custom

    Description

    Selects which Led Flash Pattern to configure

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    Yes

    Value range

    See enum entries table below.

    Default value

    LedFlashPattern1

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Led Flash Pattern Selector Enum Entries:

    Name

    Description

    LedFlashPattern1

    Led Flash Pattern 1

    LedFlashPattern2

    Led Flash Pattern 2

    LedFlashPattern3

    Led Flash Pattern 3

    LedFlashPattern4

    Led Flash Pattern 4

    Out1 OnTime

    Name

    LedFlashOut1OnTime[LedFlashPatternSelector]

    Custom

    Description

    This controls the On time for Flash Output 1

    Interface

    Float

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    Variant

    Value Range

    ax_X

    [0.0, 3495.04]

    g8_X

    [0.0, 3276.60]

    Default value

    0.0

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Out2 OnTime

    Name

    LedFlashOut2OnTime[LedFlashPatternSelector]

    Custom

    Description

    This controls the On time for Flash Output 2

    Interface

    Float

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    Variant

    Value Range

    ax_X

    [0.0, 3495.04]

    g8_X

    [0.0, 3276.60]

    Default value

    0.0

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Out3 OnTime

    Name

    LedFlashOut3OnTime[LedFlashPatternSelector]

    Custom

    Description

    This controls the On time for Flash Output 3

    Interface

    Float

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    Variant

    Value Range

    ax_X

    [0.0, 3495.04]

    g8_X

    [0.0, 3276.60]

    Default value

    0.0

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Out4 OnTime

    Name

    LedFlashOut4OnTime[LedFlashPatternSelector]

    Custom

    Description

    This controls the On time for Flash Output 4

    Interface

    Float

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    Variant

    Value Range

    ax_X

    [0.0, 3495.04]

    g8_X

    [0.0, 3276.60]

    Default value

    0.0

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Pattern Off Delay

    Name

    LedFlashPatternOffDelay[LedFlashPatternSelector]

    Custom

    Description

    This increases the duration of the specified pattern

    Interface

    Float

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    Variant

    Value Range

    ax_X

    [0.0, (3495.04 – MaxOutXOnTime)]

    g8_X

    [0.0, (3276.60 – MaxOutXOnTime)]

    MaxOutXOnTime is the maximum of the flash out on time of the specified pattern.

    Default value

    0.0

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Pattern duration

    Name

    LedFlashPatternDuration[LedFlashPatternSelector]

    Custom

    Description

    This is the resulting duration of the specified pattern

    Interface

    Float

    Access mode

    Read Only

    Adjustable

    while grabbing

    -

    Value range

    The value depends on the minimum line time and on the maximum flash out on time of the specified pattern.

    Default value

    -

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    -

    Led Flash Frame Control

    Name

    LedFlashFrameControl

    Custom

    Description

    Determine if Led flash signals are generated continuously or only while image scan

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See enum entries table below.

    Availability

    ALL

    Default value

    Continuous

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Led Flash Frame Control Enum Entries:

    Name

    Description

    Continuous

    Flash pulses are generated continuously

    ImageFrame

    Flash pulses are generated only during image scan

    Led Flash Sequence Time

    Name

    LedFlashSequenceTime

    Custom

    Description

    This is the time to repeat all defined pattern in free-run mode.

    Interface

    Float

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    Variant

    Value Range

    ax_X

    [(MinLineTime * NoOfPattern), 13980.8]

    g8_X

    [(MinLineTime * NoOfPattern), 13107.0]

    The minimum value depends on different factors like minimum line time of the system together with number of patterns.

    Default value

    -

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.