To open the Options dialog box, click Settings on the Start menu.
Option name | Default value | Description |
Wait for image timeout | 30000 | If the next image is not received after the specified time, then it will send a timeout. The value can be modified. When GCT is restarted, it is set back to 30000. |
Heartbeat timeout | 3000 | Read the value of GevHeartbeatTimeout from the camera (control channel). |
Data Stream Buffer Count | 5 | Specifies the number of buffers used for each stream. The value should be at least 2 or 3. |
Ignore Image Timeout | Not selected | Can be selected if the acquisition process should continue despite timeout error. |
Display Corrupt Image | Not selected | Can be selected if an image should be displayed despite missing data |
Stops If an Error Occurs | Not selected | |
Draw | All | Can be set to display every x frames, or to shut off display to reduce CPU usage. |
Enable XML feature caching | Not selected | So that the actual value is retrieved directly from the camera, instead of from a cached register. |
The options (except Wait for image timeout and Heartbeat timeout) are saved in GCC.ini