    The Device status code is organized in two parts. The upper two bytes define a status category. The lower two bytes define the specific status that occurred in this category.

    Device Status Category (Upper 2 bytes)

    This section contains an overview of the status categories codes. This is again divided into 2 parts. The upper 1 byte contain the error category.

    Definition

    Value

    Description

    NO_ERROR

    0x00

    No error status category

    WARNING

    0x01

    Warning status category

    ERROR

    0x02

    Error status category

    The lower 1 byte contain the component code:

    Definition

    Value

    Description

    SYSTEM

    0x00

    System status category

    ILLUMINATION

    0x01

    Illumination status category

    SENSOR

    0x02

    Sensor status category

    TRANPORT LAYER

    0x03

    Transport layer status category

    Specific status (Lower 2 bytes)

    This section contains the specific status codes (lower part of the DeviceStatusCode) grouped by the category. This again divided into 2 parts. The upper 1 byte for the specific component id and lower 1 byte for the error code.

    1. System and Illumination

    Definition

    Value

    Description

    DEV_STATUS_OK

    0x0000

    OK

    DEV_STATUS_WARNING_

    TEMPERATURE_TOO_HIGH

    0x0001

    Warning: Device temperature high.

    DEV_STATUS_ERROR_

    TEMPERATURE_TOO_HIGH

    0x0002

    Error: Device temperature too high.

    DEV_STATUS_ERROR_ILLUM_

    TEMPERATURE_TOO_HIGH

    0x0003

    Error: Illumination temperature too high.

    DEV_STATUS_ERROR_ILLUM_LED_ERROR

    0x0004

    Error: Illumination Error.

    1. Sensor
    • G8

    Definition

    Value

    Description

    SENSOR_STATUS_G8_PGOOD_ERROR

    0x0101

    Error: g8 sensor PGOOD error.

    SENSOR_STATUS_G8_TRAINING_DONE_ERROR

    0x0102

    Error: g8 sensor training done error.

    • P6

    Definition

    Value

    Description

    SENSOR_STATUS_P6_TRAINING_DONE_ERROR

    0x0201

    Error: p6 sensor training done error.

    SENSOR_STATUS_P6_INIT_ERROR

    0x0202

    Error: p6 sensor initialization error

    1. Transport layer
    • Cxp

    Definition

    Value

    Description

    TL_STATUS_WARNING_CXP_LINK_CONFIGURATION

    0x0301

    Warning: Cxp link configuration invalid.

    • Gige

    Definition

    Value

    Description

    TL_STATUS_WARNING_LICENSING_

    AUTHENTICATION_FAILED

    0x0401

    Warning: License authentication failed. It is in evaluation mode, the stream channel will be closed after 20-30min.