ID5 Connector

Prev Next

Cable with wire end ferrules

This connecting cable is used to connect the Corona II to LED control units other than the XLC4 control unit.

The number of anode and cathode pairs depends on the number of connected Corona II modules. Each 170 mm basic module requires one anode and cathode pair.

Anschlussstecker 1_v01
example: cable with wire end ferrules for 4 Corona II modules

Cable with terminal blocks

This connecting cable is used to connect the Corona II to the XLC4 control unit.

Anschlussstecker 2_v01
example: cable with terminal blocks in standard configuration for 4 Corona II modules

The connector with 6 wires is present in all configurations. For each Corona II module an additional connector with anode and cathode connection is required.

Cable with Hummel connector

Some applications require an additional connection closer to the Corona II module and higher protection classes. Therefore a Hummel connector can be used. This is useful if the Corona II module must be replaced.

Pins of the Hummel connector

pin

cable color

signal

1 (A)

black

A1+

2 (B)

white-black

C1–

3 (C)

brown

A2+

4 (D)

white-brown

C2–

5 (E)

grey

A3+

6 (F)

white

C3–

7 (G)

orange

A4+

8 (H)

yellow

C4–

9 (I)

red

Vcc

10 (J)

blue

GND3

11 (K)

purple

SCL

12 (L)

green

SDA

13 (M)

white-red

fan+

14 (N)

white-green

fan–

15 (O)

white-orange

fan status

16 (P)

white-yellow

reserved

Drag chain cabling option

In addition to the standard cabling there is the drag chain cabling option available.

parameter

drag chain cable

regular cable

diameter [mm]

9.0

8.5

bending radius - moving

7.5 × diameter

15 × diameter

bending radius - static

4 × diameter

7.5 × diameter