Command VT
    • 04 Jul 2024
    • 1 Minute to read
    • PDF

    Command VT

    • PDF

    Article summary

    Command VT is used to read the values of the supply voltage.

    Structure

    Command

    Notes

    CommandID

    VT

    VT works in all XLC4 operating modes

    Parameter

    None

    Parameter

    Value

    Description

    None

    The current values of the supply voltage are queried

    Response

    vt, space, input , analog , channel 1, channel 2, channel 3, channel 4

    General notes

    The output values are in mV. For the voltage of the LEDs apply a factor of 18,46.

    Example

    Query

    Response

    Action

    VT

    vt 24758,0,1347,1343,1350,1350

    Displays the current values:

    Supply voltage: 24,758 mV

    Analog input voltage: 0 mV

    LED voltage at channel 1: 1,347 mV × 18.46 = 24,866 mV

    LED voltage at channel 2: 1,343 mV × 18.46 = 24,792 mV

    LED voltage at channel 3: 1,350 mV × 18.46 = 24,921 mV

    LED voltage at channel 4: 1,350 mV × 18.46 = 24,921 mV

    SV 22000,25500

    sv 22000,25500

    The new values are set:

    • 22000 mV mimimum level

    • 25500 mV maximum level


    Was this article helpful?