Command FA
    • 04 Jul 2024
    • 1 Minute to read
    • PDF

    Command FA

    • PDF

    Article summary

    Command FA is used to set the content of the control register “ControlFlagsA”.

    Structure

    Command

    Notes

    CommandID

    FA

    Only available in Command mode

    Parameter

    None

    Register value

    HexChar

    Parameter

    Value

    Description

    None

    The current value is queried

    Register value

    0x0000

    Default value

    0x0001

    Service

    For service use only – set to 0

    0x0002

    Internal

    For internal use only – set to 0

    0x0004

    ActSW

    XLC4-1 and XLC4-1A:

    Activate use of Switch

    (SW1 to SW2 at connector X6)

    0x0008

    ActVO

    Activate use of VOUT

    (VOUT at connector X5)

    0x0010

    CheckFan

    Supervise Fan-valid signal

    (ACNTRL at connector X5)

    0x0020

    Enable

    ON

    Activates flash function

    (Signal ON at connector X6)

    0x0200

    Channel

    control

    mode

    XLC4-1F4:

    All channels are controlled independent from the inputs at X6

    Response

    fa , space , register value

    General notes

    The register value is applied after switching on again.

    Combinations of single flags are possible.

    Example with Register value

    Query

    Response

    FA 0x000C

    fa 0x000C

    Activates VOUT and SW1-SW2 for cooling device.

    ControlFlagA

    HexChar

    Reserved

    Reserved

    EnableON

    CheckFan

    ActVO

    ActSW

    Internal

    use

    Service

    Description

    0x0000

    0

    0

    0

    0

    0

    0

    0

    0

    ON disabled, no FAN control or

    external cooling device control

    0x0004

    0

    0

    0

    0

    0

    1

    0

    0

    ON disabled, Standard mode with

    cooling device at SW1-SW2

    0x0008

    0

    0

    0

    0

    1

    0

    0

    0

    ON disabled, Standard mode with

    Fan at VOUT

    0x000C

    0

    0

    0

    0

    1

    1

    0

    0

    ON disabled, VOUT and SW1-SW2

    active for cooling device

    0x0020

    0

    0

    1

    0

    0

    0

    0

    0

    Switching XLC4 with ON-Input - no

    cooling device connected

    0x0024

    0

    0

    1

    0

    0

    1

    0

    0

    Switching XLC4 with ON-Input -

    cooling device at SW1-SW2

    0x0028

    0

    0

    1

    0

    1

    0

    0

    0

    Switching XLC4 with ON-Input - Fan

    at VOUT

    0x002C

    0

    0

    1

    0

    1

    1

    0

    0

    Switching XLC4 with ON-Input -

    VOUT and SW1-SW2 active for

    cooling device

    0x0018

    0

    0

    x

    1

    1

    x

    0

    0

    Activating the fan monitoring

    functions


    Was this article helpful?

    What's Next
    ESC

    Eddy AI, facilitating knowledge discovery through conversational intelligence