    Acquisition Mode

    Name

    AcquisitionMode

    Standard

    Description

    Sets the acquisition mode of the device. It defines mainly the number of frames to capture during an acquisition and the way the acquisition stops.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See enum entries table below.

    Default value

    Continuous

    Availability

    ALL

    Notes

    -

    Error behavior

    -

    Acquisition Mode Enum Entries:

    Name

    Description

    Continuous

    Frames are captured continuously until stopped with the AcquisitionStop command.

    SingleFrame

    One Frame is captured.

    Acquisition Start

    Name

    AcquisitionStart

    Standard

    Description

    Starts the Acquisition of the device. The number of frames captured is specified by AcquisitionMode.

    Interface

    Command

    Access mode

    Read/Write

    Adjustable

    while grabbing

    Yes

    Value range

    1

    Default value

    1

    Availability

    ALL

    Notes

    -

    Error behavior

    Success is returned on successful start otherwise some error code.

    See the device error code documentation.

    Acquisition Stop

    Name

    AcquisitionStop

    Standard

    Description

    Stops the Acquisition of the device at the end of the current Frame.

    Interface

    Command

    Access mode

    Read/Write

    Adjustable

    while grabbing

    Yes

    Value range

    [0, 1]

    For writing only command value 1 is supported.

    Default value

    1

    Availability

    ALL

    Notes

    The command will return immediately however it is not finished and will continue execution in background.
    As soon as the command value changes from 1 to 0 the command has finished.
    Features locked by TLParamsLocked can be modified first after AcquisitionStop has finished execution completely.

    Error behavior

    See the device error code documentation.

    Acquisition Abort

    Name

    AcquisitionAbort

    Standard

    Description

    Aborts the Acquisition immediately.

    Interface

    Command

    Access mode

    Read/Write

    Adjustable

    while grabbing

    Yes

    Value range

    [0, 1]

    For writing only command value 1 is supported.

    Default value

    1

    Availability

    ALL

    Notes

    When command is executed, it aborts the current frame immediately without completing the current frame.

    Error behavior

    See the device error code documentation.

    Frame Count

    Name

    FrameCount

    Standard

    Description

    Indicates the number of frames captured during an acquisition period.

    Interface

    Integer

    Access mode

    Read only

    Adjustable

    while grabbing

    -

    Value range

    [0, 65535]

    Default value

    1

    Availability

    ALL

    Notes

    This feature value will be resetted during an UserSet load.

    Error behavior

    -

    Exposure Time Mode

    Name

    ExposureTimeMode

    Standard

    Description

    Sets the configuration mode of the Exposure Time feature.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See enum entries table below.

    Default value

    Common

    Availability

    ALL

    Notes

    -

    Error behavior

    See the device error code documentation.

    Exposure Time Mode Enum Entries:

    Name

    Availability

    Description

    Common

    ALL

    The exposure time is common to all the color components.

    Individual

    g8_X

    The exposure time is individual for each color component.

    Exposure Time Selector

    Name

    ExposureTimeSelector

    Standard

    Description

    Selects which exposure time is controlled by the Exposure Time feature. This allows for independent control over the exposure components.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See enum entries table below.

    Default value

    Common

    Availability

    ALL

    Notes

    -

    Error behavior

    See the device error code documentation.

    Exposure Time Selector Enum Entries:

    Name

    Availability

    Description

    Common

    ALL

    Selects the common ExposureTime.

    White

    g8_X

    Selects the White ExposureTime.

    Infrared

    g8_X

    Selects the Infrared ExposureTime.

    Red

    g8_X

    Selects the Red ExposureTime.

    Green

    g8_X

    Selects the Green ExposureTime.

    Blue

    g8_X

    Selects the Blue ExposureTime.

    Exposure Time

    Name

    ExposureTime[ExposureTimeSelector]

    Standard

    Description

    This controls the duration during which the photosensitive cells are exposed to light.

    Interface

    Float

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    Freerun:

    The exposure time must be smaller than the Acquisition Line Time plus an offset.

    LineTirgger On or Salve camera (MSMode is set to Slave):

    The exposure time must be smaller than the maximum exposure time.


    The minimum difference of Acquisition Line Time and ExposureTime are camera variant specific. Therefore, query the min and max entries of this feature.

    Default value

    30

    Availability

    ALL

    Notes

    The unit is micro-seconds.

    Error behavior

    See the device error code documentation.

    Acquisition Integration Time – Deprecated

    Name

    AcquisitionIntegrationTime

    Custom

    Description

    Controls the integration time. (unit: micro-seconds)

    Interface

    Float

    Access mode

    Read/Write

    Adjustable

    while grabbing

    -

    Value range

    See the value range of Exposure Time

    Default value

    -

    Notes

    This feature is deprecated please use Exposure Time instead.

    Error behavior

    See the device error code documentation.

    Acquisition Integration Time Min – Deprecated

    Name

    AcquisitionIntegrationTimeMin

    Custom

    Description

    Displays the minimum integration time. (unit: micro-seconds)

    Interface

    Float

    Access mode

    Read only

    Adjustable

    while grabbing

    -

    Value range

    Default value

    -

    Notes

    This feature is deprecated; query the min and max values from Exposure Time instead.

    Error behavior

    -

    Acquisition Line Rate

    Name

    AcquisitionLineRate

    Standard

    Description

    Controls the rate (in Hertz) at which the Lines in a Frame are captured.

    Interface

    Float

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    [(1 / Acquisition Line Time.Max), (1 / Acquisition Line Time.Min)]

    Default value

    18.18 KHz

    Availability

    ALL

    Notes

    This is the inverse of the Acquisition Line Time

    This feature is not available if MasterSlaveMode is configured as Slave or LedFlashEnable is enabled.

    Error behavior

    See the device error code documentation.

    Acquisition Line Rate Max – Deprecated

    Name

    AcquisitionLineRateMax

    Custom

    Description

    This value is calculated by the camera. It limits the AcquisitionLineRate. The unit is Hertz.

    Interface

    Float

    Access mode

    Read only

    Adjustable

    while grabbing

    -

    Value range

    -

    Default value

    -

    Notes

    Please use the min and max node entries of the Acquisition Line Rate feature.

    Error behavior

    -

    Acquisition Line Time

    Name

    AcquisitionLineTime

    Custom

    Description

    Controls the processing time per scan line.

    Interface

    Float

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    The value range depends on:

    Query the min and max values of the acquisition line time feature to get the valid range for current setting.

    The exposure time always must be smaller than the line time:
    Range defined by exposure time: [Exposure Time + gap μs, 27900 μs]

    Gap = {ax_X = 1.5 ; g8_X = 2.0}

    Example range for gige-vision with one and two physical links connected.

    1. [37.431 μs, 13981 μs] – For single link (10Gbps) + ax_X
    2. [30.881 μs, 13981 μs] – For dual link (20Gbps) + ax_X
    3. [37.431 μs, 13107.1875 μs] – For single link (10Gbps) + g8_X
    4. [30.881 μs, 13107.1875 μs] – For dual link (20Gbps) + g8_X

    1 For Region Width: 15360, GevSCPSPacketSize: 8240 and AcquisitionFrameRate disabled.

    Default value

    55

    Availability

    ALL

    Notes

    This is the inverse of the Acquisition Line Rate .

    If AcquisitionLineTime is set for higher values, then make sure to adopt image timeout to avoid timeout issues while grabbing.

    This parameter influences the value range of AcquisitionFrameRate. Please read the AcquisitionFrameRate feature documentation for further details.

    This feature is not available if MasterSlaveMode is configured as Slave or LedFlashEnable is enabled.

    Error behavior

    See the device error code documentation.

    Acquisition Line Time Min – Deprecated

    Name

    AcquisitionLineTimeMin

    Custom

    Description

    Displays the minimum processing time per scan line in μs.

    Interface

    Float

    Access mode

    Read only

    Adjustable

    while grabbing

    -

    Value range

    [Exposure Time + 1.5 μs]

    Default value

    -

    Notes

    Please query the min and max values of the Acquisition Line Time feature instead of using this feature.

    Error behavior

    -

    Acquisition Frame Rate Enable

    Name

    AcquisitionFrameRateEnable

    Standard

    Description

    Controls whether the AcquisitionFrameRate feature is writable and used to control the acquisition rate. Otherwise, the acquisition rate is implicitly controlled by the combination of other features such as AcquisitionLineTime.

    Interface

    Boolean

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    True, False

    Default value

    False

    Availability

    ALL

    Notes

    The FrameActive and FrameStart triggers must be set to Off to enable this feature.

    This feature is not available if MasterSlaveMode is configured as Slave or LedFlashEnable is enabled.

    Error behavior

    See the device error code documentation.

    Acquisition Frame Rate

    Name

    AcquisitionFrameRate

    Standard

    Description

    Controls the acquisition rate (in Hertz) at which the frames are captured.

    Interface

    Float

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    The value range depends on the line time as well as on the image height:

    Min Acquisition Frame Rate:

    Max Acquisition Frame Rate:

    Default value

    10

    Availability

    ALL

    Notes

    The Acquisition Frame Rate is based on the given AcquisitionLineTime even if a line trigger is used. Therefore, the real frame rate depends on the line trigger if this is used. The accuracy of this feature is limited.

    This feature is writeable only if AcquisitionFrameRateEnable is set to True.

    Changing the image height or the acquisition line time influences the value range of the AcquisitionFrameRate. It may be that while these parameters are changed. The current value for the AcquisitionFrameRate gets out of range. In this case the real acquisition frame rate is clamped internally to the maximum possible frame rate.

    This feature is not available if MasterSlaveMode is configured as Slave or LedFlashEnable is enabled.

    Error behavior

    See the device error code documentation.

    Time Delay Integration Mode

    Name

    TimeDelayIntegrationMode

    Custom

    Description

    Selects the Time Delay Integration Mode. This is not enabling or disabling the TDI, but choosing if high sensitivity or a high dynamic range is desired.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See enum entries table below.

    Default value

    HighSensitivity

    Availability

    ALL

    Notes

    • Enabling the TDI will be done by setting the TimeDelayIntegration feature to a value greater than 1
    • The DSNU and PRNU data sets must be created with the desired TDI Mode. When changing the mode, the DSNU/PRNU references must be recreated.

    Error behavior

    See the device error code documentation.

    Exposure Time Mode Enum Entries:

    Name

    Availability

    Description

    HighSensitivity

    ALL

    The sensivitiy will be increased in this TDI mode.

    This is achieved by summing up the lines.

    HighSNR

    ALL

    Opposed to HighSensitivity this mode leads to a higher dynamic range. The SNR will be greater.

    This is achieved by averaging the lines.

    Time Delay Integration

    Name

    TimeDelayIntegration

    Custom

    Description

    Selects the number of photo-sensitive cells combined (average).

    Interface

    Integer

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    [1, 3]

    Default value

    1

    Availability

    ALL

    Notes

    This feature is available for the Mono Cameras and the g8 sensor.
    For the g8 sensor the sensor hardware revision should be at least 2 to support this feature for RGB(Ir). The sensor hardware version can be retrieved by the Device Version feature.

    Error behavior

    See the device error code documentation.

    Master Slave Mode

    Name

    MasterSlaveMode

    Custom

    Description

    Specifies the master slave mode of the camera.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See enum entries table below.

    Default value

    Off

    Availability

    ALL

    Notes

    Whenever the Master and Slave camera maximum operating line frequency differs make sure to configure the Master to operate in the lower speed. Otherwise, the images delivered by Slave may be corrupt.

    The camera’s maximum line frequency may differ e.g., by different Width, Pixel Format, Decimation Horizontal Float, Binning Horizontal or Exposure Time parameter.

    To be sure about the setting check the maximum value of Acquisition Line Rate by querying it from the camera.

    The following features are not available if the mode is set to Slave or AutoSelect (Slave):

    Error behavior

    See the device error code documentation.

    Master Slave Mode Enum Entries:

    Name

    Description

    Off

    No master slave is selected.

    Master

    Selects the camera to be Master.

    Slave

    Selects the camera to be Slave.

    AutoSelect

    Automatically selects the camera to be either Master or Slave.

    AutoSelect (Master)

    This is available if AutoSelect is selected. If Line3 is in low level, then AutoSelect in Master mode.

    AutoSelect (Slave)

    This is available if AutoSelect is selected. If Line3 via pull-up(high level), then AutoSelect in Slave Mode.

    Master Slave Interface - Deprecated

    Name

    MasterSlaveInterface[MasterSlaveMode]

    Custom

    Description

    Specifies the interface type to be used for master/slave.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See enum entries table below.

    Default value

    External

    Availability

    ALL

    Notes

    This feature is deprecated, use MasterSlaveSource, MasterSlaveAutoSelectSource and Digital IO configuration.
    It will be removed from package 3.0.0

    For External interface,

    Master – Line9 as output

    Slave – Line4 as input and Line9 as output

    Error behavior

    See the device error code documentation.

    Master Slave Interface Enum Entries:

    Name

    Description

    External

    Interface between master and slave camera is external(physical)

    Internal

    Interface between master and slave camera is internal

    Master Slave Interface Enable - Deprecated

    Name

    MasterSlaveInterfaceEnable[MasterSlaveInterface]

    Custom

    Description

    Enables the selected master/slave interface.

    Interface

    Boolean

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    True – Enables selected master/slave interface.

    False – Disables selected master/slave interface.

    Default value

    False

    Availability

    ALL

    Notes

    This feature is deprecated, use MasterSlaveSource, MasterSlaveAutoSelectSource and Digital IO configuration.
    It will be removed from package 3.0.0

    Error behavior

    See the device error code documentation.

    Master Slave Source

    Name

    MasterSlaveSource

    Custom

    Description

    Specifies the source to be used for master/slave.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See enum entries table below.

    Default value

    Off

    Availability

    ALL

    Notes

    Only Line4 and Line11 are available for allPIXAEvo

    Error behavior

    See the device error code documentation.

    Master Slave Source Enum Entries:

    Name

    Description

    Line1

    Specifies physical line (or pin) Line1 to use as source for the master slave signal.

    Line2

    Specifies physical line (or pin) Line2 to use as source for the master slave signal.

    Line3

    Specifies physical line (or pin) Line3 to use as source for the master slave signal.

    Line4

    Specifies physical line (or pin) Line4 to use as source for the master slave signal.

    Line5

    Specifies physical line (or pin) Line5 to use as source for the master slave signal.

    Line6

    Specifies physical line (or pin) Line6 to use as source for the master slave signal.

    Line7

    Specifies physical line (or pin) Line7 to use as source for the master slave signal.

    Line8

    Specifies physical line (or pin) Line8 to use as source for the master slave signal.

    Line9

    Specifies physical line (or pin) Line9 to use as source for the master slave signal.

    Line10

    Specifies physical line (or pin) Line10 to use as source for the master slave signal.

    Line11

    Specifies physical line (or pin) Line11 to use as source for the master slave signal.

    AutoSelect Source

    Name

    MasterSlaveAutoSelectSource

    Custom

    Description

    Specifies the source to be used for AutoSelect.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See enum entries table below.

    Default value

    Off

    Availability

    ALL

    Notes

    Only Line3 is available for allPIXAEvo

    Error behavior

    See the device error code documentation.

    AutoSelect Source Enum Entries:

    Name

    Description

    Line1

    Specifies physical line (or pin) Line1 to use as source for the autoselect signal.

    Line2

    Specifies physical line (or pin) Line2 to use as source for the autoselect signal.

    Line3

    Specifies physical line (or pin) Line3 to use as source for the autoselect signal.

    Line4

    Specifies physical line (or pin) Line4 to use as source for the autoselect signal.

    Line5

    Specifies physical line (or pin) Line5 to use as source for the autoselect signal.

    Line6

    Specifies physical line (or pin) Line6 to use as source for the autoselect signal.

    Line7

    Specifies physical line (or pin) Line7 to use as source for the autoselect signal.

    Line8

    Specifies physical line (or pin) Line8 to use as source for the autoselect signal.

    Line9

    Specifies physical line (or pin) Line9 to use as source for the autoselect signal.

    Slave DelayLines

    Name

    MasterSlaveDelayLines

    Custom

    Description

    Specifies the delay in number of lines for the slave camera.

    Interface

    Integer

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    The value range varies when led flash is enabled depending on the number of patterns.

    1. [0 , 32764] – LedFlashEnable is disabled
    2. [0,  32764] – LedFlashEnable is enabled and NumberOfPattern=1
    3. [0,  16382] – LedFlashEnable is enabled and NumberOfPattern=2
    4. [0,  10921] – LedFlashEnable is enabled and NumberOfPattern=3
    5. [0,  8191] – LedFlashEnable is enabled and NumberOfPattern=4

    Default value

    0

    Availability

    ALL

    Notes

    This feature is valid and available only for the Slave Camera.

    Error behavior

    See the device error code documentation.

    Acquisition Burst Frame Count

    Name

    AcquisitionBurstFrameCount

    Standard

    Description

    Specifies the number of frames to acquire for each FrameBurstStart trigger

    Interface

    Integer

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    [1 , AcquisitionBurstFrameCount Max]

    Default value

    1

    Availability

    ALL

    Notes

    This feature is valid and available only for FrameBurstStart and if MasterSlaveMode is not configured as Slave.

    Error behavior

    See the device error code documentation.

    Trigger Selector

    Name

    TriggerSelector

    Standard

    Description

    Selects the type of trigger to configure.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    Yes

    Value range

    See enum entries table below.

    Default value

    FrameStart

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Trigger Selector Enum Entries:

    Name

    Description

    FrameStart

    Selects a trigger starting the capture of one frame.

    FrameActive

    Selects a trigger controlling the duration of one frame.

    FrameBurstStart

    Selects a trigger starting of the bursts of frames in an acquisition.

    LineStart

    Selects a trigger starting the capture of one Line of a Frame.

    Trigger Mode

    Name

    TriggerMode[TriggerSelector]

    Standard

    Description

    Controls whether the selected trigger is active.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See enum entries table below.

    Default value

    Off

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Trigger Mode Enum Entries:

    Name

    Description

    Off

    Disables the selected trigger.

    On

    Enables the selected trigger.

    Trigger Source

    Name

    TriggerSource[TriggerSelector]

    Standard

    Description

    Specifies the internal signal or physical input Line to use as the trigger source.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See the enum entries for more information.

    Default value

    -

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Trigger Source Enum Entries:

    Name

    Description

    Notes

    Encoder0

    Specifies Encoder0 signal to use as internal source for the trigger.

    This enum entry is valid and available only for LineStart

    Line1

    Specifies physical line (or pin) Line1 and associated I/O control block to use as external source for the trigger signal.

    This enum entry is valid and available only for LineStart

    Line2

    Specifies physical line (or pin) Line2 and associated I/O control block to use as external source for the trigger signal.

    This enum entry is valid and available only for Frame Trigger

    Line3

    Specifies physical line (or pin) Line3 and associated I/O control block to use as external source for the trigger signal.

    This enum entry is valid and available for Frame or Line trigger

    Line4

    Specifies physical line (or pin) Line4 and associated I/O control block to use as external source for the trigger signal.

    This enum entry is valid and available for Frame or Line trigger

    Trigger Activation

    Name

    TriggerActivation[TriggerSelector]

    Standard

    Description

    Specifies the activation mode of the trigger.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    Yes

    Value range

    See enum entries table below.

    Default value

    -

    Availability

    ALL

    Notes

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Trigger Activation Enum Entries:

    Name

    Description

    Notes

    RisingEdge

    Specifies that the trigger is considered valid on the rising edge of the source signal.

    This enum entry is valid and available only for LineStart or FrameStart or FrameBurstStart

    FallingEdge

    Specifies that the trigger is considered valid on the falling edge of the source signal.

    This enum entry is valid and available only for FrameStart or FrameBurstStart

    LevelHigh

    Specifies that the trigger is considered valid if the level of the source signal is high.

    This enum entry is valid and available only for FrameActive

    LevelLow

    Specifies that the trigger is considered valid if the level of the source signal is low.

    This enum entry is valid and available only for FrameActive

    Trigger DelayLines

    Name

    TriggerDelayLines[TriggerSelector]

    Custom

    Description

    Specifies the delay in number of lines to apply after the trigger reception before activating it

    Interface

    Integer

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    The value range varies when led flash is enabled depending on the number of patterns.

    1. [0 , 32764] – LedFlashEnable is disabled
    2. [0,  32764] – LedFlashEnable is enabled and NumberOfPattern=1
    3. [0,  16382] – LedFlashEnable is enabled and NumberOfPattern=2
    4. [0,  10921] – LedFlashEnable is enabled and NumberOfPattern=3

    [0,  8191] – LedFlashEnable is enabled and NumberOfPattern=4

    Default value

    0

    Availability

    ALL

    Notes

    This feature is valid and available only for FrameStart, FrameBurstStart and FrameActive.

    This feature is not available if MasterSlaveMode is configured as Slave.

    Error behavior

    See the device error code documentation.

    Trigger Divider

    Name

    TriggerDivider[TriggerSelector]

    Standard

    Description

    Specifies a division factor for the incoming line trigger pulses

    Interface

    Integer

    Access mode

    Read/Write

    Adjustable

    while grabbing

    Yes

    Value range

    [1 , 256]

    Default value

    1

    Availability

    ALL

    Notes

    This feature is valid and available only for LineStart and if MasterSlaveMode is not configured as Slave.

    Error behavior

    See the device error code documentation.

    Trigger Signal Detection Mode

    Name

    TriggerSignalDetectionMode[TriggerSelector]

    Custom

    Description

    Specifies the debounce type to be evaluated.

    Interface

    Enumeration

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    See enum entries table below.

    Default value

    FrameStart  - PeakholderDetection

    FrameBurstStart - PeakholderDetection

    FrameActiveDebouncing4Lines

    Availability

    ALL

    Notes

    This feature is valid and available only for FrameStart, FrameBurstStart and FrameActive and if MasterSlaveMode is not configured as Slave.

    The incoming Frame Trigger Signal can be delayed by the Trigger Delay Lines feature.

    Error behavior

    See the device error code documentation.

    Trigger Signal Detection Mode Enum Entries:

    Name

    Description

    PeakholderDetection

    Peakholder detects very short input pulse. (Sensitive to spikes.)

    Debouncing4Clocks

    Debouncing 4 clocks.
    Very short debouncing by four FPGA internal clock cycles.

    Debouncing4Lines

    Debouncing 4 lines.
    Requires a 4-line stable trigger input signal, this leads to an image delay of 4 lines.

    Debouncing60Lines

    Debouncing 60 lines.
    Requires a 60 line stable trigger input signal, leading to an image delay of 60 lines.

    Extend Lines

    Name

    FrameActiveExtendLines[TriggerSelector]

    Custom

    Description

    Specifies the number of additional output lines for FrameActive.

    Interface

    Integer

    Access mode

    Read/Write

    Adjustable

    while grabbing

    No

    Value range

    [0, 65535]

    Default value

    0

    Availability

    ALL

    Notes

    This feature is valid and available only for FrameActive and if MasterSlaveMode is not configured as Slave.

    Error behavior

    See the device error code documentation.

    Line Time (Measured)

    Name

    MeasuredLineTime[TriggerSelector]

    Custom

    Description

    Measure the processing time per scan line during line/encoder trigger in us.

    Interface

    Float

    Access mode

    Read only

    Adjustable

    while grabbing

    -

    Value range

    In freerun this feature holds the same value as AcquisitionLineTime.

    During LineStart mode ‘ON’, it displays the actual line trigger speed.

    But in both cases the maximum line time it can display is 13,107 us.

    Default value

    -

    Availability

    ALL

    Notes

    This feature is valid and available only for LineStart and if MasterSlaveMode is not configured as Slave.

    Error behavior

    Line Trigger Status

    Name

    LineTriggerStatus[TriggerSelector]

    Custom

    Description

    Display the line trigger status.

    Interface

    Enumeration

    Access mode

    Read only

    Adjustable

    while grabbing

    -

    Value range

    See enum entries table below.

    Default value

    -

    Availability

    ALL

    Notes

    This feature is valid and available only for LineStart and if MasterSlaveMode is not configured as Slave.

    Error behavior

    -

    Line Trigger Status Enum Entries:

    Name

    Description

    OK

    OK

    SpeedToHigh

    Speed to high


    Was this article helpful?